Fuses

Photo Mfr. Part # Availability Price Quantity Datasheet Package/Case Series Packaging Product Status Mounting Type Fuse Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Response Time Breaking Capacity @ Rated Voltage Melting I²t Approval Agency Operating Temperature Color Size / Dimension
FSD-10A

FSD-10A

FUSE GLASS 10A 250VAC 5X20MM

OptiFuse

3,552
RFQ
FSD-10A

Datasheet

FSD Bulk Active Requires Holder Cartridge, Glass 10 A 250 V - Fast Blow 35A 244.4 cURus, IEC 60127 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
TSC-6.3A

TSC-6.3A

FUSE GLASS 6.3A 250VAC 5X20MM

OptiFuse

3,413
RFQ
TSC-6.3A

Datasheet

TSC Bulk Active Requires Holder Cartridge, Glass 6.3 A 250 V - Slow Blow 200A 73.07 cULus, UL 248 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
FSD-3.15A

FSD-3.15A

FUSE GLASS 3.15A 250VAC 5X20MM

OptiFuse

3,164
RFQ
FSD-3.15A

Datasheet

FSD Bulk Active Requires Holder Cartridge, Glass 3.15 A 250 V - Fast Blow 35A 22.33 cURus, IEC 60127 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
FSA-1A

FSA-1A

FUSE GLASS 1A 250VAC 3AB 3AG

OptiFuse

3,143
RFQ
FSA-1A

Datasheet

FSA Bulk Active Requires Holder Cartridge, Glass 1 A 250 V - Fast Blow 100A 0.968 cULus, UL 248 -55°C ~ 125°C - 0.250" Dia x 1.252" L (6.35mm x 31.80mm)
FSA-5A

FSA-5A

FUSE GLASS 5A 250VAC 3AB 3AG

OptiFuse

3,093
RFQ
FSA-5A

Datasheet

FSA Bulk Active Requires Holder Cartridge, Glass 5 A 250 V - Fast Blow 200A 72.54 cULus, UL 248 -55°C ~ 125°C - 0.250" Dia x 1.252" L (6.35mm x 31.80mm)
FSA-3.15A

FSA-3.15A

FUSE GLASS 3.15A 250VAC 3AB 3AG

OptiFuse

3,045
RFQ
FSA-3.15A

Datasheet

FSA Bulk Active Requires Holder Cartridge, Glass 3.15 A 250 V - Fast Blow 100A 25.7 cULus, UL 248 -55°C ~ 125°C - 0.250" Dia x 1.252" L (6.35mm x 31.80mm)
FSA-3.5A

FSA-3.5A

FUSE GLASS 3.5A 250VAC 3AB 3AG

OptiFuse

2,891
RFQ
FSA-3.5A

Datasheet

FSA Bulk Active Requires Holder Cartridge, Glass 3.5 A 250 V - Fast Blow 100A 32.15 cULus, UL 248 -55°C ~ 125°C - 0.250" Dia x 1.252" L (6.35mm x 31.80mm)
FSA-400MA

FSA-400MA

FUSE GLASS 400MA 250VAC 3AB 3AG

OptiFuse

2,869
RFQ
FSA-400MA

Datasheet

FSA Bulk Active Requires Holder Cartridge, Glass 400 mA 250 V - Fast Blow 100A 0.0515 cULus, UL 248 -55°C ~ 125°C - 0.250" Dia x 1.252" L (6.35mm x 31.80mm)
FSA-4A

FSA-4A

FUSE GLASS 4A 250VAC 3AB 3AG

OptiFuse

2,598
RFQ
FSA-4A

Datasheet

FSA Bulk Active Requires Holder Cartridge, Glass 4 A 250 V - Fast Blow 200A 43.65 cULus, UL 248 -55°C ~ 125°C - 0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TSC-250MA

TSC-250MA

FUSE GLASS 250MA 250VAC 5X20MM

OptiFuse

2,130
RFQ
TSC-250MA

Datasheet

TSC Bulk Active Requires Holder Cartridge, Glass 250 mA 250 V - Slow Blow 100A 0.278 cULus, UL 248 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
FSD-2.5A

FSD-2.5A

FUSE GLASS 2.5A 250VAC 5X20MM

OptiFuse

2,083
RFQ
FSD-2.5A

Datasheet

FSD Bulk Active Requires Holder Cartridge, Glass 2.5 A 250 V - Fast Blow 35A 13.69 cURus, IEC 60127 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
TSC-500MA

TSC-500MA

FUSE GLASS 500MA 250VAC 5X20MM

OptiFuse

1,960
RFQ
TSC-500MA

Datasheet

TSC Bulk Active Requires Holder Cartridge, Glass 500 mA 250 V - Slow Blow 100A 1.9567 cULus, UL 248 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
TSC-6A

TSC-6A

FUSE GLASS 6A 250VAC 5X20MM

OptiFuse

1,747
RFQ
TSC-6A

Datasheet

TSC Bulk Active Requires Holder Cartridge, Glass 6 A 250 V - Slow Blow 200A 69.59 cULus, UL 248 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
FSD-1A

FSD-1A

FUSE GLASS 1A 250VAC 5X20MM

OptiFuse

1,738
RFQ
FSD-1A

Datasheet

FSD Bulk Active Requires Holder Cartridge, Glass 1 A 250 V - Fast Blow 35A 1.24 cURus, IEC 60127 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
TSC-800MA

TSC-800MA

FUSE GLASS 800MA 250VAC 5X20MM

OptiFuse

1,678
RFQ
TSC-800MA

Datasheet

TSC Bulk Active Requires Holder Cartridge, Glass 800 mA 250 V - Slow Blow 100A 1.03 cULus, UL 248 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
FSA-9A

FSA-9A

FUSE GLASS 9A 250VAC 3AB 3AG

OptiFuse

1,638
RFQ
FSA-9A

Datasheet

FSA Bulk Active Requires Holder Cartridge, Glass 9 A 250 V - Fast Blow 200A 296.4 cULus, UL 248 -55°C ~ 125°C - 0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TSD-6.3A

TSD-6.3A

FUSE GLASS 6.3A 250VAC 5X20MM

OptiFuse

1,549
RFQ
TSD-6.3A

Datasheet

TSD Bulk Active Requires Holder Cartridge, Glass 6.3 A 250 V - Slow Blow 35A 187.8 cURus, IEC 60127 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
FSA-750MA

FSA-750MA

FUSE GLASS 750MA 250VAC 3AB 3AG

OptiFuse

1,535
RFQ
FSA-750MA

Datasheet

FSA Bulk Active Requires Holder Cartridge, Glass 750 mA 250 V - Fast Blow 100A 0.399 cULus, UL 248 -55°C ~ 125°C - 0.250" Dia x 1.252" L (6.35mm x 31.80mm)
FSD-500MA

FSD-500MA

FUSE GLASS 500MA 250VAC 5X20MM

OptiFuse

1,460
RFQ
FSD-500MA

Datasheet

FSD Bulk Active Requires Holder Cartridge, Glass 500 mA 250 V - Fast Blow 35A 0.205 cURus, IEC 60127 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
TSD-1.6A

TSD-1.6A

FUSE GLASS 1.6A 250VAC 5X20MM

OptiFuse

1,384
RFQ
TSD-1.6A

Datasheet

TSD Bulk Active Requires Holder Cartridge, Glass 1.6 A 250 V - Slow Blow 35A 6.89 cURus, IEC 60127 -55°C ~ 125°C - 0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER