| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
C308F-V-125MA-TR1FUSE CERAMIC 125MA 250VAC/VDC |
1,280 |
|
Datasheet |
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 125mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
C308F-V-160MA-TR1FUSE CERAMIC 160MA 250VAC/VDC |
303 |
|
Datasheet |
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 160mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
EAC10-40FUSE 500V 40A CARTRIDGE |
448 |
|
Datasheet |
EAC10 | Cartridge, Non-Standard | Tray | Active | Requires Holder | Cartridge | 40A | 500 VAC | - | - | Electrical, Industrial, Motor Protection | - | - | - | - | 2kA | 0.402" Dia x 1.283" L (10.20mm x 32.60mm) | - | - |
|
EAC10-63FUSE 500V 63A CARTRIDGE |
309 |
|
Datasheet |
EAC10 | Cartridge, Non-Standard | Tray | Active | Requires Holder | Cartridge | 63A | 500 VAC | - | - | Electrical, Industrial, Motor Protection | - | - | - | - | 2kA | 0.402" Dia x 1.283" L (10.20mm x 32.60mm) | - | - |
|
C308F80MA-TRFUSE CERAMIC 80MA 250VAC/VDC |
1,131 |
|
Datasheet |
C308F | Cartridge, Non-Standard | Tape & Reel (TR) | Active | Surface Mount | Cartridge, Ceramic | 80mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.120" Dia x 0.343" L (3.05mm x 8.70mm) | - | - |
|
C308F-V-100MA-TR1FUSE CERAMIC 100MA 250VAC/VDC |
1,425 |
|
Datasheet |
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 100mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
0259001.TFUSE BRD MNT 1A 125VAC/VDC RAD |
577 |
|
Datasheet |
259 | Radial, Can, Horizontal | Bulk | Active | Through Hole | Board Mount | 1A | 125 VAC | 125 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | Baseefa, UR | -55°C ~ 90°C | 50A AC, 300A DC | 0.315" Dia x 0.512" L (8.00mm x 13.00mm) | - | - |
|
C308F-V-250MA-TR1FUSE CERAMIC 250MA 250VAC/VDC |
1,418 |
|
Datasheet |
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 250mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
0259.500TFUSE BRD MNT 500MA 125VAC/VDC |
472 |
|
Datasheet |
259 | Radial, Can, Horizontal | Bulk | Active | Through Hole | Board Mount | 500mA | 125 VAC | 125 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | Baseefa, UR | -55°C ~ 90°C | 50A AC, 300A DC | 0.315" Dia x 0.512" L (8.00mm x 13.00mm) | - | - |
|
ITV9550L2030MRFUSE BATTERY PROTECTOR 20V 45A |
961 |
|
Datasheet |
POLYSWITCH®, ITV9550 | Nonstandard SMD | Tape & Reel (TR) | Active | Surface Mount | Board Mount | 30A | - | 62 VDC | Fast Blow | Battery Protection | 14 ~ 23.4V Triggerable | - | cURus, TUV | -10°C ~ 65°C | 80A | 0.366" L x 0.197" W x 0.079" H (9.30mm x 5.00mm x 2.00mm) | - | - |
|
|
157.5701.6171FUSE STRIP 175A 48VDC BOLT MOUNT |
227 |
|
Datasheet |
- | Metal Strip | Bulk | Active | Bolt Mount | Fuse Strip | 175A | - | 48 VDC | - | Lift Trucks | Indicating | - | cURus | -40°C ~ 125°C | 1.05kA | 3.228" L x 0.866" W x 0.413" H (82.00mm x 22.00mm x 10.50mm) | - | - |
|
SCF9550-45-04FUSE TRIGGERABLE 45A 80V 4 CELL |
5,973 |
|
Datasheet |
SCF9550 | Nonstandard SMD | Tape & Reel (TR) | Active | Surface Mount | Board Mount | 45A | - | 80 VDC | Fast Blow | Battery Protection | 13 ~ 18.4V Triggerable | - | cURus | -20°C ~ 60°C | 120A | 0.374" L x 0.197" W x 0.091" H (9.50mm x 5.00mm x 2.30mm) | - | - |
|
C308F-V-40MA-TR1FUSE CERAMIC 40MA 250VAC/VDC |
1,333 |
|
Datasheet |
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 40mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
C308F-V-50MA-TR1FUSE CERAMIC 50MA 250VAC/VDC |
537 |
|
Datasheet |
C308F | Cartridge, Non-Standard (Axial) | Tape & Reel (TR) | Active | Through Hole | Cartridge, Ceramic | 50mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -55°C ~ 125°C | 4kA | 0.124" Dia x 0.343" L (3.14mm x 8.70mm) | - | - |
|
EAC10-40-PCBFUSE 500V 40A PCB TERM |
434 |
|
Datasheet |
EAC10 | Radial Bend Cylinder | Tray | Active | Through Hole | Cartridge | 40A | 500 VAC | - | - | Electrical, Industrial, Motor Protection | - | - | cURus | - | 2kA | 0.484" Dia x 1.315" L (12.30mm x 33.40mm) | - | - |
|
0305.500HFUSE BRD MNT 500MA 277VAC/VDC |
300 |
|
Datasheet |
PICO® 305 | Radial, Can, Horizontal | Bulk | Active | Through Hole | Board Mount | 500mA | 277 VAC | 277 VDC | - | Hazardous Locations | Intrinsically Safe | - | ATEX, cURus, IECEx | -40°C ~ 74°C | 1.5kA | 0.354" Dia x 0.614" L (9.00mm x 15.60mm) | - | - |
|
EAC10-63-TFUSE 500V 63A BOLT DOWN |
395 |
|
Datasheet |
EAC10 | Cylindrical, Blade Terminal (Bolt) | Tray | Active | Bolt Mount | Cartridge | 63A | 500 VAC | - | - | Electrical, Industrial, Motor Protection | - | - | - | - | 2kA | 0.409" Dia x 1.283" L (10.40mm x 32.60mm) | - | - |
|
EAC10-50-PCBFUSE 500V 50A PCB TERM |
358 |
|
Datasheet |
EAC10 | Radial Bend Cylinder | Tray | Active | Through Hole | Cartridge | 50A | 500 VAC | - | - | Electrical, Industrial, Motor Protection | - | - | cURus | - | 2kA | 0.484" Dia x 1.315" L (12.30mm x 33.40mm) | - | - |
|
EAC10-63-PCBFUSE 500V 63A PCB TERM |
328 |
|
Datasheet |
EAC10 | Radial Bend Cylinder | Tray | Active | Through Hole | Cartridge | 63A | 500 VAC | - | - | Electrical, Industrial, Motor Protection | - | - | cURus | - | 2kA | 0.484" Dia x 1.315" L (12.30mm x 33.40mm) | - | - |
|
EAC10-50-TFUSE 500V 50A BOLT DOWN |
305 |
|
Datasheet |
EAC10 | Cylindrical, Blade Terminal (Bolt) | Tray | Active | Bolt Mount | Cartridge | 50A | 500 VAC | - | - | Electrical, Industrial, Motor Protection | - | - | - | - | 2kA | 0.409" Dia x 1.283" L (10.40mm x 32.60mm) | - | - |